Mode 1: Central Hot Water: Constant Temperature, Sufficient Water Volume, 24-hour Instant Supply.
Mode 2: Central Cooling: Water Cooled Air Conditioning, Soft Air Supply, Comfortable for Human Body.
Mode 3: Whole House Heating: Water Cycled Floor Heat-ing,Well-distributed Heat Dissipation, Healthy & Energy Saving.
Mode 4: Hot Water + House Cooling: Meet the Requirements of Both Central Hot Water and Air Conditioning.
Mode 5: Hot Water + House Heating: Meet the Requirements of Both Central Hot Water and Room Heating.
Models |
EW6DCR-32 |
EW9DCR-32 |
EW12DCR-32 |
EW14DCR-32 |
EW16DCR-32 |
EW19SDCR-32 |
||
Heating (at A20/W35°C ) |
Heating Capacity |
kW |
8.44 |
12.1 |
16.32 |
18.76 |
21.88 |
25.4 |
Power Input |
kW |
1.41 |
2.02 |
2.77 |
3.47 |
3.66 |
4.5 |
|
COP |
W/W |
5.99 |
5.99 |
5.89 |
5.41 |
5.98 |
5.64 |
|
Heating (at A7/W35°C ) |
Heating Capacity |
kW |
6.21 |
8.90 |
12 |
13.80 |
16.3 |
18.7 |
Power Input |
kW |
1.26 |
1.81 |
2.5 |
3.13 |
3.34 |
4.06 |
|
COP |
W/W |
4.93 |
4.92 |
4.8 |
4.41 |
4.88 |
4.61 |
|
Heating (at A7/W45°C ) |
Heating Capacity |
kW |
5.91 |
8.46 |
11.29 |
13.11 |
15.31 |
17.78 |
Power Input |
kW |
1.48 |
2.12 |
3.08 |
3.67 |
3.88 |
4.75 |
|
COP |
W/W |
3.99 |
3.99 |
3.67 |
3.57 |
3.95 |
3.74 |
|
Heating (at A2/W35°C ) |
Heating Capacity |
kW |
5.56 |
7.97 |
10.80 |
12.42 |
14.49 |
16.8 |
Power Input |
kW |
1.22 |
1.76 |
2.44 |
3.06 |
3.23 |
3.97 |
|
COP |
W/W |
4.56 |
4.53 |
4.43 |
4.06 |
4.49 |
4.23 |
|
Heating (at A2/W45°C) |
Hooling Capacity |
kW |
5.32 |
7.61 |
10.16 |
11.80 |
13.78 |
16 |
Power Input |
kW |
1.45 |
2.07 |
3.01 |
3.60 |
3.8 |
4.65 |
|
COP |
W/W |
3.67 |
3.68 |
3.38 |
3.28 |
3.63 |
3.44 |
|
Cooling (at A35/ W18ºC ) |
Cooling Capacity |
kW |
6.35 |
8.1 |
11.00 |
13.10 |
15.6 |
16.6 |
Power Input |
kW |
1.55 |
1.99 |
2.87 |
3.51 |
3.9 |
4.3 |
|
EER |
W/W |
4.10 |
4.07 |
3.83 |
3.73 |
4 |
3.86 |
|
Cooling (at A35/W7ºC ) |
Cooling Capacity |
kW |
4.90 |
5.9 |
8.10 |
9.50 |
11.4 |
12.4 |
Power Input |
kW |
1.60 |
1.96 |
2.63 |
3.35 |
3.5 |
3.95 |
|
EER |
W/W |
3.06 |
3.01 |
3.08 |
2.84 |
3.26 |
3.14 |
|
Compressor |
Mitsubishi |
|||||||
Max.currentt |
A |
13 |
13 |
19 |
20 |
25 |
9 |
|
Electric supply |
230V/50-60Hz |
230V/1Phase or 400V/3Phase 50~60HZ |
||||||
Max.water temperature ( oC) |
60 |
|||||||
Running temperature range (oC) |
-25 ~ 43 |
|||||||
Refrigerant circuit | Refrigerant |
R32 |
||||||
DC Inverter compressor(s) |
Twin Rotary |
|||||||
Heat exchange |
Copper and Hydrauphilic Aluminum Fin |
|||||||
Air flow |
m3/h |
2100 |
2400 |
2900 |
3100 |
5600 |
5600 |
|
Water circuit | Heat exchanger |
Plate heat exchanger |
||||||
In/Out pipe |
DN25(1”) |
DN25(1”) |
DN32 |
|||||
Water flow |
m3/h |
≥0.8 |
≥1.2 |
≥1.8 |
≥2.0 |
≥2.3 |
≥2.3 |
|
permitted pressure |
≤0.8MPa |